Other options

Attenuator set

The trigger option is effective for low repetition frequencies (below the frame rate).
Mainly for measuring pulsed light. It is used to synchronize laser and camera exposures, especially when measuring low repetitive pulses below 10 Hz.
The pulsed laser (10Hz) will not be visible unless the camera is synchronized at 30Hz.
The trigger option is not required if the repetition frequency is about 100Hz or higher, such as when measuring pulses. The trigger option is recommended for low repetitions such as 10Hz.

How to select options

Laser specification Reference value Recommended options
Power < 100 mW 1. Insert ND filter set (NDFS-CA50)
< 1 W (vertical polarization)
< 10 W (horizontal polarization)
2. Attenuating optics set with beam splitter
< 100 W 3. Attenuating optics set with double beam splitter
Beam diameter > 30 um
< 30 um 3. Micro-beam measurement set.

ND filter set (NDFS-CA50)

In order to measure a high-intensity laser beam, an ND filter set (NDFS-CA50) that can be dimmed and its mount are required.
ND-filter

Fig: ND filter set (NDFS-CA50)

ND filter diagonal mount specification

Fig: ND filter diagonal mount specification

Price: USD 1,034 (excluding tax)
Lead time: Contact us
* If the laser beam power becomes stronger than 100 mW, the absorption lens ND filter (NDFS-CA50) will generate a thermal lens effect, so a beam splitter that can further reduce the light is required.
  • Absorption ND filter (NDFS-CA50)
  • OD=0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 1.0, 2.0, 3.0, 4.0
  • 1 inch
  • With ND filter diagonal mount

Attenuating optics set with beam splitter

Fig: Attenuating optics set with beam splitter

Model number: OAS-CA50
Price: USD 1,628 (excluding tax)
Lead time: Contact us
  • LaseView camera set series LaseView-CA50-NCG compatible
  • Wavelength range: 350-700 nm or 650-1100 nm
  • Power:< 1 W(For vertically polarized light) < 10 W(For horizontally polarized light)
  • ND filter (NDFS-CA50)included:OD=2.0, 3.0, 4.0, 5.0

* Can be attached directly to the camera.
* The attenuation factor of the beam splitter varies depending on the polarization direction. (P-polarized 0.9%, S-polarized 9%)
* Although the ND filter (NDFS-CA50) has an AR coating, interference fringes may occur if the coherence of the laser beam is high.
* An appropriate attenuation rate is not guaranteed under the specified incident light conditions.
Add or replace an ND filter (NDFS-CA50) with an appropriate attenuation factor according to the conditions.
* There are the following restrictions on beam polarization.
・ Horizontal or vertical linear polarization
・ Uniform polarization characteristics throughout the beam
・ If these conditions are not met, the correct intensity distribution may not be measured due to the polarization dependence of the beam splitter.
* Posts for height adjustment and fixing are not included.

Attenuating optics set with double beam splitter

Fig: Attenuating optics set with double beam splitter

Model number: OAS-CA50-100
Price: USD 2,750 (excluding tax)
Lead time: Contact us
  • LaseView camera set series LaseView-CA50-NCG compatible
  • Wavelength range: 350-700 nm or 650-1100 nm
  • Estimated power: <100 W
  • ND filter included: OD = 1.0, 2.0, 3.0, 4.0

* Can be attached directly to the camera.
* Although the ND filter is AR coated, interference fringes may occur if the coherence of the laser beam is high.
* We do not guarantee an appropriate attenuation rate under the specified incident light conditions.
Add or replace an ND filter with an appropriate attenuation factor according to the conditions.
* Posts for height adjustment and fixing are not included.

Attenuating optics set with double beam splitter for UV

Fig: Attenuating optics set with double beam splitter

Model number: OAS-CA50-100-UV
Price: USD 3,740 (excluding tax)
Lead time: Contact us
  • LaseView camera set series LaseView-CA50-NCG compatible
  • Wavelength range: 200~700 nm
  • Estimated power: <100 W
  • ND filter included: OD = 1.0, 2.0, 3.0

* Can be attached directly to the camera.
* Although the ND filter is AR coated, interference fringes may occur if the coherence of the laser beam is high.
* We do not guarantee an appropriate attenuation rate under the specified incident light conditions.
Add or replace an ND filter with an appropriate attenuation factor according to the conditions.
* Posts for height adjustment and fixing are not included.

Attenuating optics set with double beam splitter for NIR

Fig: Attenuating optics set with double beam splitter

Model number: OAS-CA50-100-NIR
Price: USD 3,740 (excluding tax)
Lead time: Contact us
  • LaseView camera set series LaseView-CA50-NCG compatible
  • Wavelength range: 1000〜2600 nm
  • Estimated power: <100 W
  • ND filter included: OD = 1.0, 2.0, 3.0

* Can be attached directly to the camera.
* Although the ND filter is AR coated, interference fringes may occur if the coherence of the laser beam is high.
* We do not guarantee an appropriate attenuation rate under the specified incident light conditions.
Add or replace an ND filter with an appropriate attenuation factor according to the conditions.
* Posts for height adjustment and fixing are not included.

3. Micro-beam measurement set

In order to measure beams smaller than 30 μm, a set of microbeam measurement optics is required. As a set of microbeam measurement optics, we have achieved “”high magnification, high NA, and ultra-low aberration”” that is not available anywhere else.

微小ビーム測定光学系 外観図
Fig. Micro-beam measurement set
  • Magnification: Approx. 30x (typical value 30.8x @1064 nm, 31.5x @532 nm)
  • NA: 0.4
  • Wavelength range: 400~1100 nm (recommended 600~1100 nm)
  • Optical resolution: < 2 μm
  • Working distance:Around 1.7 mm((typical value 1.7 mm @1064 nm、1.6 mm @532 nm)
  • Length: 176 mm
  • Can be connected to CCD camera

Price: USD 891 (excluding tax) (camera not included)
Delivery time: Contact us

4. Microbeam measurement optical system set + dedicated holder + 3-axis stage

In order to measure beams of several micrometers in size, a 3-axis (x, y, z) stage with micrometer-level position adjustment is required.

微小ビーム測定光学系セット及び専用ホルダと3軸ステージ仕様
Fig. Micro-beam measurement set, dedicated holder and 3-axis stage specifications
  • Micro operating position: Side
  • Travel guide: Ball guide
  • Travel distance per revolution: 0.5 mm
  • Micrometer minimum reading: 0.01mm
  • Travel distance〔mm〕:XY axis ±6.5, Z axis ±5
  • Can be mounted on a table with M6 tapping.

Price: USD 2,211(excluding tax) (Camera not included)
Delivery time: Contact us