LaseView-LHB lineup
LaseView-LHB
Light receiving surface size | 50 mm × 50 mm |
---|---|
Optical resolution | Around 100 μm(※1) |
Measurement wavelength range | 400 – 1100 nm (Focus is made with 532 nm or 1060 nm) |
Power supply | Camera power supply 5 V About 250 mA (supplied from the USB) Motor power supply 6 V 100 mA or less (supplied from the included AC adapter) |
Size(mm) | W154 × H82.5 × D130 (Excluding stand, cable and AC adapter) |
Weight | 2 kg or less (Excluding stand, cable and AC adapter) |
Software | Comply with LaseView |
Remark |
|
Price | contact us |
Lead time | contact us |
※ 1 Typically, the resolution as specified is obtained over the entire light-receiving surface. However, the inspection before shipment is limited to the center.
Diagram
Catalog
LaseView-LHB-GigE
Interface GigE type
(The basic usage is the same as the above LaseView-LHB. Only the differences are listed.)
Power supply | Camera power supply 12 V About 400 mA (supplied from the included AC adapter) or 48V (supplied from PoE compatible devices via LAN cable) Motor power supply 6 V, 100 mA or less (supplied from the included AC adapter) |
---|---|
Size(mm) | W168 × H82.5 × D130 (Excluding stand, cable and AC adapter) |
Remark |
|
Price | contact us |
Lead time | contact us |
Diagram
<About the configuration of LaseView-LHB-GigE>
※ USB 3.0 connector is used when connecting to a PC.
※ The external trigger connector is used when taking an external trigger.
※ The motor power connector and motor switch are used when using the speckle reduction function.
Catalog
LaseView-LHB-100
Light receiving surface size | 100 mm × 100 mm |
---|---|
Optical resolution | Around 200 μm(※1) |
Measurement wavelength range | 400 – 1100 nm (Focus is made with 532 nm or 1060 nm) |
Power supply | Camera power supply 4.5 to 5.5 V About 250 mA (supplied from the USB) Motor power supply 6 V 100 mA or less (supplied from the included AC adapter) |
Size(mm) | W208 × H137 × D173 (Excluding stand, cable and AC adapter) |
Weight | 2.5 kg or less (Excluding stand, cable and AC adapter) |
Software | Comply with LaseView |
Remark |
|
Price | contact us |
Lead time | contact us |
※ 1 Typically, the resolution as specified is obtained over the entire light-receiving surface. However, the inspection before shipment is limited to the center.
Diagram
Catalog
LaseView-LHB-NIR-GigE
Light receiving surface size | 50mm × 50mm |
---|---|
Optical resolution | Around 400 μm(※1) |
Measurement wavelength range | 950 – 1700 nm (Focus is made with 1310 nm) |
Power supply | 12V, 10W or less (Supplied from the included AC adapter) |
Size(mm) | W195 × H83 × D196 (Excluding stand, cable and AC adapter) |
Weight | 2.5 kg or less (Excluding stand, cable and AC adapter) |
Software | Comply with LaseView |
Remark |
|
Price | contact us |
Lead time | contact us |
※ 1 Typically, the resolution as specified is obtained over the entire light-receiving surface. However, the inspection before shipment is limited to the center.
LaseView-LHB-100-NIR-GigE
Light receiving surface size | 100mm × 100mm |
---|---|
Optical resolution | Around 800 μm(※1) |
Measurement wavelength range | 950 – 1700 nm (Focus is made with 1310 nm) |
Power supply | 12V, 10W or less (Supplied from the included AC adapter) |
Size(mm) | W215 × H137 × D219 (Excluding stand, cable and AC adapter) |
Weight | 2.5 kg or less (Excluding stand, cable and AC adapter) |
Software | Comply with LaseView |
Remark |
|
Price | contact us |
Lead time | contact us |
※ 1 Typically, the resolution as specified is obtained over the entire light-receiving surface. However, the inspection before shipment is limited to the center.
LaseView-LHB-VISNIR-GigE
Light receiving surface size | 50mm × 50mm |
---|---|
Optical resolution | Around 150 μm(※1) |
Measurement wavelength range | 400~1700nm (Focus is made with 1310 nm) |
Power supply | Undecided (Supplied from the included AC adapter) |
Size(mm) | W195 × H83 × D196 (Excluding stand, cable and AC adapter) |
Weight | 2.5 kg or less (Excluding stand, cable and AC adapter) |
Software | Comply with LaseView |
Remark |
|
Price | contact us |
Lead time | contact us |
※ 1 Typically, the resolution as specified is obtained over the entire light-receiving surface. However, the inspection before shipment is limited to the center.
Diagram
Catalog
LaseView-LHB-100-VISNIR-GigE
Light receiving surface size | 100mm × 100mm |
---|---|
Optical resolution | Around 300 μm(※1) |
Measurement wavelength range | 400~1700nm (Focus is made with 1310 nm) |
Power supply | Undecided (Supplied from the included AC adapter) |
Size(mm) | W215 × H137 × D219 (Excluding stand, cable and AC adapter) |
Weight | 2.5 kg or less (Excluding stand, cable and AC adapter) |
Software | Comply with LaseView |
Remark |
|
Price | contact us |
Lead time | contact us |
※ 1 Typically, the resolution as specified is obtained over the entire light-receiving surface. However, the inspection before shipment is limited to the center.
Diagram
Catalog
LaseView-LHB-100-WA
Light receiving surface size | 100 mm x 100 mm (horizontal x vertical) |
---|---|
Optical resolution | Approx. 200 µm (at the centre of the photosensitive area) |
Approximate measurement power density | 0.1~100 W/cm2 (sensitivity adjusted according to exposure time) |
Incident power density | Max. 100 W/cm2 |
Total incident power | Max. 10 W |
Allowable incident light angle | ±70° |
Measurement wavelength range | 400-1100 nm (focus adjusted at specified wavelength at time of shipment) |
Number of CCD effective pixels | 2048 x 1536 (horizontal x vertical) |
Number of acquired image pixels | 1600 x 1600 (horizontal x vertical) |
A/D conversion resolution | 12 bit |
Frame rate | 60 fps (max) |
Exposure time | 25 μs~4 s |
Interface | USB3.1 |
External trigger function | Yes (3.3 to 24 V) |
Power supply | Camera power supply 4.75 – 5.25 V, approx. 360 mA (supplied via USB) Motor power supply 6 V, 100 mA or less (supplied by attached AC adaptor) |
External dimensions | as shown in the attached diagram |
Weight | 2.5 kg or less (excluding stand, cables and AC adapter) |
Software functions | LaseViewに準拠 |
Remarks |
|
Diagram
LaseView LHB-UHP
Light receiving surface size | 50 mm × 50 mm |
---|---|
Optical resolution | Around 100 μm(※1) |
Indication of measurement power density | 10~100 kW/cm2 |
Total incident power | Maximum 10 W |
Incident power density | Up to 100 kW/cm2 (High heat resistant screen) |
Allowed incident light angle | ±15° |
Measurement wavelength range | 400~1100 nm (Focus is made with 532 nm) |
Image sensor pixel(mm) | 1440 × 1080 (Horizontal × vertical) |
Acquisition image pixel | 1250 × 1250 (Horizontal × vertical) |
A/D Conversion resolution | 8 / 12 bit |
Frame rate | 160 fps |
Exposure time | 1 μs~30 s |
Interface | USB3.0(miniB terminal) |
External trigger | Yes(3.3~12 V / 820 Ω) |
Power supply | Camera power supply 5 V, About 660 mA (supplied from the USB) Motor power supply 6 V, 100 mA or less (supplied from the included AC adapter) |
Size(mm) | W154 × H82.5 × D164 (Excluding stand, cable and AC adapter) |
Weight | 2 kg or less (Excluding stand, cable and AC adapter) |
Software | Comply with LaseView |
Remark |
|
Price | contact us |
Lead time | contact us |
※ 1 Typically, the resolution as specified is obtained over the entire light-receiving surface. However, the inspection before shipment is limited to the center.
LaseView LHB-100-UHP
Light receiving surface size | 100 mm × 100 mm |
---|---|
Indication of measurement power density | 10~100 kW/cm2(UHP model) |
Total incident power | Maximum 10 W |
Allowed incident light angle | ±15° |
Optical resolution | Approx.200 μm |
Measurement wavelength range | 400~1100 nm(Focus adjusted at specified wavelengths) |
Sensor effective pixels | 2048×1536 |
Number of acquired image pixels | 2000×2000 |
bit depth | 8 / 16 bit |
Frame rate | 60 fps(Maximum) |
Exposure time | 25 μs~4 s |
Interface | USB 3.0 |
Power supply | Camera power supply 5V (supplied from the USB) |
Motor power supply 6V (supplied from the included AC adapter) | |
Size(mm) | W208mm×H137mm×D173mm |
Remark |
|
Price | contact us |
Lead time | contact us |
LaseView LHB-200
- All in one and compact.
- No need to adjust by the users
- Having a function to reduce speckle
- Calibrated spatial scale
- Calibrated spatial distortion and homogeneous of intensity
- Less dependency of incident light angle (WA model is available for ±70°)
Light receiving surface size | 200 mm × 200 mm |
---|---|
Optical resolution (※1) |
Around 400 μm |
Measurement wavelength range | 400~1100 nm |
Power supply | 5V、Around700 mA (Supplied from the included USB) |
Motor supply | 6V、100 mA or less (Supplied from the included AC adapter) |
Size(mm) | W389 × H258 × D268 (Excluding stand, cable and AC adapter) |
Weight | 8 kg or less (Excluding stand, cable and AC adapter) |
Software | Comply with LaseView |
Remark |
|
Price | contact us |
Lead time | contact us |
※1 According to product specification, resolution is available on whole area of light-receiving surface,
Inspection prior to shipment will be made only on the center of light-receiving surface.
Diagram
Catalog
LaseView-LHB-200-VISNIR-GigE
Interface GigE type
(The basic usage is the same as the above LaseView-LHB. Only the differences are listed.)
Optical resolution | Around 600μm |
---|---|
Frame rate | 60 fps (at maximum) |
Measurement wavelength range | 950~1700nm (Adjusted at specified wavelength) |
Exposure time | 6 μs~10 s |
Interface | Gigabit Ethernet (1000BASE-T) |
Power supply | 12 V, 7 W (supplied by attached AC adaptor) |
Motor supply | 6 V, 100 mA or less (supplied by attached AC adaptor) |
Remark |
|
Price | contact us |
Lead time | contact us |
Diagram
LaseView-LHB-200-GigE
Interface GigE type
(The basic usage is the same as the above LaseView-LHB. Only the differences are listed.)
Frame rate | 24 fps (at maximum) |
---|---|
Exposure time | 20 μs~30 s |
Interface | Gigabit Ethernet (RJ-45 connector) |
Power supply | 12 V About 400 mA (supplied from the included AC adapter) or 48 V (supplied from PoE compatible devices via LAN cable) |
Motor supply | 6 V 100 mA or less (supplied from the included AC adapter) |
Remark |
|
Price | contact us |
Lead time | contact us |
※1 According to product specification, resolution is available on whole area of light-receiving surface,
Inspection prior to shipment will be made only on the center of light-receiving surface.
※ Wireless LAN is not supported because the network must support Gigabit Ethernet (1000BASE-T).
Diagram
Catalog
LaseView LHB-25
Light receiving surface size | 25 mm × 25 mm |
Optical resolution | Around 50 μm |
Measurement wavelength range | 400~1100 nm(Focus is made depending on the designated wavelength) |
Power supply | 5 V(Supplied from the included USB) |
Motor supply | 6 V(Supplied from the included AC adapter) |
Size(mm) | W129 × H57.5 × D116 |
Remark | In case of small beam diamater, sufficient resolution may not be available. |
Frame rate decrease depending on the PC’s Computing ability or USB terminal. | |
In case of using speckle reduction function, 1 – 2 second (typical) measurement time is needed. | |
Price | contact us |
Lead time | contact us |
※1 According to product specification, resolution is available on whole area of light-receiving surface,
Inspection prior to shipment will be made only on the center of light-receiving surface.
Diagram
※1 According to product specification, resolution is available on whole area of light-receiving surface,
Inspection prior to shipment will be made only on the center of light-receiving surface.
※ Wireless LAN is not supported because the network must support Gigabit Ethernet (1000BASE-T).
Catalog
Specification
model | LHB-25 | LHB / LHB-GigE | LHB-NIR-GigE | LHB-VISNIR-GigE | LHB-UHP |
---|---|---|---|---|---|
Light receiving surface size (mm) | 25 × 25 | 50 × 50 | 50 × 50 | 50 × 50 | 50 × 50 |
Optical resolution (※ 1) | Around 50 μm | Around 100 μm | Around 400 μm | Around 150 μm | Around 100 μm |
Indication of measurement power density (※ 2) |
0.1~100 W/cm2 (※ 2) |
0.1~100 W/cm2 (※3) | 0.1~100 W/cm2 | 0.1~100 W/cm2 | 10~100 kW/cm2 |
Total incident power (※4) | Maximum 10W | Maximum 10W | Maximum 10W | Maximum 10W | Maximum 10W |
Allowed incident light angle (※5) | ±15° | ±15° | ±15° | ±15° | ±15° |
Measurement wavelength range (default focus wavelength) | 400~1100 nm (Focus is made depending on the designated wavelength) | 400~1100 nm (532 nm or 1060 nm) | 950〜1700 nm (1550 nm) | 400~1700nm (1310nm) | 400~1100 nm (532 nm) |
Image sensor pixel(mm) (Horizontal × vertical) | 1440 × 1080 | 1440×1080 | 320 × 256 | 1280 × 1024 | 1440 × 1080 |
Acquisition image pixel (Horizontal × vertical) | 1600 × 1600 | 1600×1600 | 400 × 400 | 1250 × 1250 | 1250 × 1250 |
A/D Conversion resolution | 8 / 16 bit | 8 / 16 bit | 8 / 10 / 12 / 14 bit | 8 / 10 / 12 bit | 8 / 12 bit |
Frame rate (at maximum) |
238 fps | 238 fps | 228fps | 130 fps(8 bit) | 160 fps |
Exposure time | 1 μs ~ 30 s | 1 μs~30 s | 0.001 ms~ 10 ms | – | 1 μs~30 s |
Interface | USB 3.0 | USB3.0(miniB) / GigE(RJ-45) | GigE(RJ-45) | GigE(RJ-45) | USB3.0(miniB) |
External trigger | – | Yes (3.3~24 V / 3.5 mA) | – | – | Yes |
model | LHB-100 | LHB-100-NIR-GigE | LHB-100-VISNIR-GigE | LHB-100-WA |
---|---|---|---|---|
Light receiving surface size (mm) |
100 × 100 | 100 × 100 | 100 × 100 | 100 × 100 |
Optical resolution (※ 1) |
Around 200 μm | Around 800 μm | Around 300 μm | Around 200 μm |
Indication of measurement power density (※ 2) |
0.1~100 W/cm2 (※3) |
0.1~100 W/cm2 | 0.1~100 W/cm2 | 0.001~1 W/cm2 |
Total incident power (※4) |
Maximum 10W | Maximum 10W | Maximum 10W | Maximum 10W |
Allowed incident light angle (※5) |
±15° | ±15° | ±15° | ±70° |
Measurement wavelength range (default focus wavelength) |
400~1100 nm (532 nm or 1060 nm) |
950〜1700 nm (1550 nm) |
400~1700nm (1310nm) |
400~1100 nm |
Image sensor pixel(mm) (Horizontal × vertical) |
2048×1536 | 320 × 256 | 1280 × 1024 | 2048 × 1536 |
Acquisition image pixel (Horizontal × vertical) |
1600 × 1600 | 400 × 400 | 1250 × 1250 | 1600 × 1600 |
A/D Conversion resolution | 8 / 16 bit | 8 / 12 bit | 8 / 10 / 12 / 14 bit | 12 bit |
Frame rate (at maximum) |
60 fps | 228fps | 130 fps (8 bit) |
60 fps |
Exposure time | 1 μs~30 s | 0.001 ms~ 10 ms | – | 25 μs~4 s |
Interface | USB3.0(miniB) | GigE(RJ-45) | GigE(RJ-45) | USB3.1 |
External trigger | Yes (3.3~12 V / 820Ω) |
– | – | Yes (3.3~24 V) |
model | LHB-200 / LHB-200-GigE | LHB-200-VISNIR-GigE |
---|---|---|
Light receiving surface size (mm) |
200 × 200 | 200 × 200 |
Optical resolution (※ 1) |
Around 400 μm | Around 600 μm |
Indication of measurement power density (※ 2) |
0.1~100 W/cm2 | 0.1~100 W/cm2 |
Total incident power (※4) |
Maximum 10W | Maximum 10W |
Allowed incident light angle (※5) |
±15° | ±15° |
Measurement wavelength range (default focus wavelength) |
400~1100 nm | 950~1700 nm |
Image sensor pixel(mm) (Horizontal × vertical) |
2448 × 2048 | 1280 × 1024 |
Acquisition image pixel (Horizontal × vertical) |
2500 × 2500 | 1250 × 1250 |
A/D Conversion resolution | 8 / 16 bit | 8 / 10 / 12bit |
Frame rate (at maximum) |
38 fps | 60 fps |
Exposure time | 25 μs~4 s / 20 μs~30 s | 6 μs~10 s |
Interface | USB3.0(3.0 Micro B)/ GigE(RJ-45) |
Gigabit Ethernet (1000BASE-T) |
External trigger | Yes (3.3~12 V / 820 Ω) |
– |
※ 2 Sensitivity adjusted according to exposure time
※ 3 1 mW / cm2 ~ by replacing the ND filter (NDFS-CA50)
※ 4 Customizable for large total incident power.
※ 5 Customizable for large allowable incident light angles.
※ Customizable in the infrared region.
※ Wireless LAN is not supported because the network must support Gigabit Ethernet (1000BASE-T).
Sales results
- Tokyo Institute of Technology
- Saga University
- Japan Coast Guard(JCG)
- Japan Aerospace Exploration Agency(JAXA)
- National Institutes for Quantum and Radiological Science and Technology(QST)
- Japan Atomic Energy Agency(JAEA)
- More than 10 domestic private companies
- More than 2 overseas private companies